        Kyoritsu 6010B | 5 In 1 Digital Multifunction Tester

        Description:

        The Kyoritsu 6010B is a 5 in 1 Digital Multifunction Tester capable of continuity, insulation, loop and RCD testing as well as measuring continuous operating voltage of a protective device (Uc). The 6010B features an easy to use handheld design with built in memory (up to 300 results) and a large dual display with bright backlight and bargraph.

        The Kyoritsu 6010B is an advanced multifunction meter that can perform continuity testing up to 200Ω with a short circuit currnet up to 200mA DC. Insulation resistance can also be measured up to 200MΩ with a 500 V DC test voltage. The 6010B integrates several safety features including a live circuit warning LED to indicate the circuit under test is live as well as integral overload protection on interal continuity and insulation test circuitry. Contact voltage (Uc) can also be measured up to 100V.

        In addition, the Kyoritsu 6010B can perform loop and RCD testing. This includes testing across a large range of currents (10/30/100/300/500 mA) and an auto ramp function. The instrument also features a built memory to store up to 300 measured results. The results can then be downloaded to PC using the optional communication adaptor and PC software.

        The Kyoritsu 6010B is supplied with test leads, case, shoulder strap and batteries.

        Features:

        • 5 in 1 Tester - Continuity, Insulation, Loop, RCD Testing and  Uc.
        • RCD Testing - 10/30/100/300/500 mA ranges, Fast Trip (40ms) and Auto Ramp  
        • Live circuit warning LED: Immediate illumination of a warning lamp if the circuit under test is live. 
        • Built-in memory (up to 300 results). 
        • 500V DC test voltage for insulation tests. 
        • 200mA short circuit current on continuity ranges. 
        • Wiring connection check LED’s: Immediate indication if wiring of circuit under test is correct (Loop & RCD).
        • Contact voltage (Uc) up to 100V.

        (6010B)

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 1 Year
        Commercial Use: 1 Year
        Warranty Method: Return to Sparky Direct

        Specifications:

        Continuity Testing
        Measuring Range 20/200Ω (Auto-Ranging)
        Open Circuit Voltage > 6V
        Short Circuit Current > 200mA
        Accuracy ±(3%rdg + 3dgt)
        Insulation Resistance Testing
        Measuring Range 20/200MΩ (Auto-Ranging)
        Test Voltage 500/1000V
        Open Circuit Voltage +20% - 0%
        Rated Current > 1mA
        Accuracy ± (3%rdg + 3dgt)
        Loop Impedance Testing
        Impedance Range 20/2000Ω
        Rated Voltage 230V + 10% - 15%(50Hz)
        Normal Test Current 20Ω:25A/10ms
        2000Ω:15mA/350ms max.
        Accuracy ±(3%rdg + 8dgt)
        RCD Testing
        Test Current
        (Test Current Duration)
        x1/2, x1 10, 30, 100, 300, 500mA (2000ms)
        Fast 150mA (50ms)
        DC 10, 30, 100, 300mA (2000ms), 500mA (200ms)
        Auto Ramp Goes up by 10% from 20% to 110% of IΔn. 300ms×10
        Rated Voltage 230V + 10% - 15% 50Hz
        Accuracy Test Current x1/2: -8%-2%
        x1, FAST: +2%+8%
        DC: ±10%
        Auto Ramp: ±4%
        Trip Time ±(1%rdg + 3dgt)
        Uc Testing
        Measuring Range 100V
        Rated Voltage 230V + 10% - 15% (50Hz)
        Test Current 5mA at IΔn = 10mA
        15mA at IΔn = 30/100mA
        150mA at IΔn = 300/500mA
        Accuracy +5% to +15%rdg±8dgt

         

        Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2
        IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
        Power source R6 or LR6 × 8
        Dimensions 115(L) × 175(W) × 86(D)mm
        Weight 840g approx.
        Included Accessories 7122B (Test leads) 
        KAMP10* (Test Lead with IEC Connector) *Australian plug
        Pouch for Test leads
        Shoulder Strap
        Shoulder Pad
        Instruction Manual
        Optional Accessories 7133B (Distribution board test leads)
        8212-RS232C (RS232C adaptor with "KEW Report (Software)")
        8212-USB (USB adaptor with "KEW Report (Software)")

         

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Kyoritsu
        SKU 6010B
        Model # 6010B
        Barcode # 4560187065347
        Package Weight 1.403kg
        Package Width 0.210m
        Package Height 0.117m
        Package Length 0.150m
        TYPE VALUE
        Type Multifunction Tester
        Brand Kyoritsu
        Dimensions 115(L) × 175(W) × 86(D)mm
        Weight 840g approx
        Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2 | IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)
        Continuity 20/200Ω 200mA Test Current
        Insulation 500/1000V, 20/200MΩ 1mA Rated Test Current
        Loop Impedance 20/2000Ω 15mA Test Current at 2000Ω (No RCD Trip)
        RCD 10/30/100/300/500mA x1/2, x1, Fast Trip(40ms), DC, Auto Ramp