        Learn more by watching our Major Tech MT575 | 10kV High Voltage Tester video.

        Major Tech | 10kV Insulation Resistance Tester 200GΩ to 2TΩ | CAT IV 600V CAT III 1000V

        The Major Tech MT575 is a digital insulation resistance tester with four test voltage ranges of 1000V, 2500V, 5000V, and 10,000V DC, rated CAT IV 600V and CAT III 1000V. It measures insulation resistance up to 2TΩ on the 10,000V range, with a short circuit current output up to 5mA for testing large plant. The MT575 also measures AC and DC voltage from 30V to 600V and stores 200 results in memory for recall on the display. A microprocessor-controlled two-line display shows the insulation reading, elapsed test time, output voltage, and output current together.

        Insulation faults in HV motors, transformers, and long cable runs rarely announce themselves before a breakdown stops production. Proving the condition of that plant needs test voltages well beyond what a 1kV megohmmeter can drive through the insulation. The MT575 applies up to 10,000V DC with auto-ranging to 2TΩ, enough stress to expose weakness a lower voltage never reveals. Its 5mA short circuit current is sized for cables, transformers, motors, generators, and large wiring installations.

        For contractors maintaining industrial plant, DAR and PI testing turns a one-off reading into trend data that supports condition reports and re-energisation decisions. Test time adjusts from 1 to 30 minutes, and the MT575 runs the timed sequence, freezes the result on auto hold, and saves it among 200 recallable stored results. Auto discharge bleeds the test object down after every run before the leads come off. The kit ships with test leads, crocodile clips, a carrying case, shoulder strap, and eight C cells.

        Features

        • Four test voltage ranges — the rotary selector sets 1000V, 2500V, 5000V, or 10,000V DC, with auto-ranging on every insulation range.
        • Insulation resistance to 2TΩ — range ceilings run 200GΩ at 1000V, 500GΩ at 2500V, 1TΩ at 5000V, and 2TΩ at 10,000V, all at ±(5% + 5 digits).
        • CAT IV 600V / CAT III 1000V — the MT575 is rated to IEC 61010-1 for utility-level and distribution-level test environments.
        • 5mA short circuit current — output current suits cables, transformers, motors, generators, insulators, and large wiring installations.
        • DAR and PI indication — dielectric absorption ratio and polarisation index results read directly from the two-line display.
        • Adjustable test time — timed tests run from 1 minute to 30 minutes, with auto hold freezing the reading at completion.
        • 200-result memory — the MT575 saves 200 measurements for recall on the display, backed by a date and time calendar.
        • Leakage current display — current measurement spans 0.5nA to 0.55mA alongside the resistance reading and output voltage.
        • 600V AC/DC voltmeter — the voltage function reads 30V to 600V at ±(2% + 3 digits); it does not resolve voltages below 30V.
        • Live circuit warning — visual and audible alarms trigger when external voltage above 30V AC or DC is present at the terminals.
        • Auto discharge — the MT575 discharges the circuit under test automatically after each measurement completes.
        • Field-ready build — a moulded case, backlit display, low battery indication, and auto power off support long days on plant, running on eight C cells.

        Where to use

        • Motor and generator maintenance — the MT575 stress-tests winding insulation at service-relevant voltages before failures take machines offline.
        • HV and MV cable testing — long feeder and submain runs test at 5000V or 10,000V where a 1kV tester cannot certify condition.
        • Transformer condition assessment — DAR and PI ratios build the moisture and contamination picture behind oil and winding decisions.
        • Switchgear and insulator checks — the MT575 proves insulation on switchgear and line insulators with measuring reach to 2TΩ.
        • Commissioning large installations — new industrial wiring proves out at 5000V and 10,000V test voltages before energisation and handover.
        • Periodic plant surveys — 200-result memory carries a full round of scheduled insulation tests back to the office in one instrument.

        The MT575 applies test voltages up to 10,000V DC and is a tool for trained personnel following safe isolation procedures; confirm the circuit is de-energised and discharged before connection. Its voltmeter function reads only from 30V to 600V, so it does not replace a general-purpose multimeter for low voltage work. The instrument warns visually and audibly when external voltage above 30V is present, and auto discharge runs after each test before leads are removed.

        (MT575)

        Four ranges select on the rotary switch: 1000V, 2500V, 5000V, and 10,000V DC, with auto-ranging on each. Maximum insulation resistance readings run from 200 gigohms on the 1000V range up to 2 teraohms on the 10,000V range.

        Dielectric absorption ratio and polarisation index compare insulation readings taken at set intervals during a timed test. The ratios indicate moisture and contamination in windings and cables, giving a condition picture that a single spot reading cannot. Both display directly on the tester.

        Yes. Up to 200 measurement results save in memory and recall onto the two-line display for review. A date and time calendar is built in, and auto hold freezes each reading when the timed test completes.

        Test time adjusts from 1 minute to 30 minutes. The display shows the insulation reading, elapsed measuring time, output voltage, and output current throughout, and the circuit discharges automatically once the test finishes.

        The tester warns visually and audibly when external voltage above 30V AC or DC is present, and it should only connect to circuits that are isolated and discharged. It is rated CAT IV 600V and CAT III 1000V to IEC 61010-1.

        Test leads, crocodile clips, a carrying case, a shoulder strap, eight C batteries, and the instruction manual. The tester runs on the eight LR14 C cells with a CR2032 cell fitted, and low battery indication shows when replacement is due.

        The MT575 carries a 2 year warranty for both domestic and commercial use, starting from the invoice date. Lodge a claim by returning the unit to Sparky Direct with proof of purchase and a fault description; it is then forwarded to Major Tech's authorised service centre for assessment. Allow 7 to 14 working days.

        The Major Tech MT575 is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        All Major Tech Meters sold through Sparky Direct are covered by the manufacturer’s warranty. If you believe your meter is faulty or defective, you may request an assessment under this warranty policy.

        How to Lodge a Warranty Claim

        To initiate a warranty claim:

        1. Return to Sparky Direct
          Ship the meter back to Sparky Direct along with:

          • A copy of your proof of purchase
          • A brief description of the issue
          • Your contact details

          Please ensure the unit is securely packaged to prevent damage in transit.

        2. Forwarded for Assessment
          Upon receiving your meter, we will forward it to Major Tech’s authorised service centre for inspection, testing, and calibration.

        Assessment Process

        Major Tech’s service lab will assess the returned unit to determine:

        • Whether the fault is due to a manufacturer’s defect (covered under warranty), or
        • If the issue is the result of user error or no fault is found.

        Outcomes

        • If approved under warranty: The product will be repaired or replaced at no cost to you.
        • If not covered under warranty: The lab may offer repair services, which will be quoted and billed directly to you by the service provider.

        Important Notes

        As Major Tech’s service labs are independent providers, Sparky Direct cannot govern or guarantee turnaround times or any costs incurred for repairs outside of warranty coverage.

        Please allow up to 7-14 working days for the return of your product.

        Function Range Resolution Accuracy
        DC voltage 30 – 600V 1V ± (2% + 3 Digits)
        AC voltage 30 – 600V 1V ± (2% + 3 Digits)
        Insulation resistance 1000V 1000V 200GΩ ± (5% + 5 Digits)
        Insulation resistance 2500V 2500V 500GΩ ± (5% + 5 Digits)
        Insulation resistance 5000V 5000V 1TΩ ± (5% + 5 Digits)
        Insulation resistance 10000V 10000V 2TΩ ± (5% + 5 Digits)
        Short circuit current 5mA    
        Overrange indication Yes    
        Polarisation index Yes    
        Dielectric absorption ratio Yes    
        Auto discharge Yes    
        Data logging Yes    
        Data Hold Yes    
        Back Light Yes    
        Enclosure Robust moulded case    
        Low battery indication Yes    
        Power source 8 x LR14, 1 x CR2032    
        Weight 2120g    
        Dimensions 250 x 190 x 127mm    
        Safety Specs IEC61010-1 CatIV 600V    

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Major Tech
        SKU MT575
        Model # MT575
        TYPE VALUE
        Type Insulation Tester
        Brand Major Tech
        Height (mm) 250
        Width (mm) 190
        Depth (mm) 127
        Power Source 8 x LR14, 1 x CR2032

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products