Skip to main content
Clipsal Deals: Win Your Height in Beer | Free Ship $290+ | Get $50 Prezzee at $600+ Click Here

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Video

    Learn more by watching our Hager ADC216B | 16Amp 10kA Single Pole RCBO video.

    Description

    Hager ADC216B | 16Amp 10kA Single Pole RCBO

    The Hager ADC216B is a 16Amp single-pole RCBO (Residual Current Circuit Breaker with overcurrent protection) designed for reliable protection in residential and commercial electrical systems. With a breaking capacity of 10kA and compliance with IEC 60898-1, this RCBO ensures safety and performance.

    The ADC216B features a C-curve, suitable for various load types, and offers 30mA residual operating current for enhanced protection against electric shocks. It operates on a 230/240V AC supply and fits DIN rail type O for easy installation.

    HAGER ADC216B Features

    • High Breaking Capacity: Rated short circuit breaking capacity of 10kA.
    • Reliable Protection: 16A rated current with 30mA residual operating current.
    • Compliant with Standards: Meets IEC 60898-1 and IEC 61009-1 standards.
    • C-Curve: Suitable for various load types.
    • Easy Installation: DIN rail type O mounting with top and bottom screw terminals.

    ADC216B FAQ

    Q: What is the breaking capacity of this RCBO?
    A: The Hager ADC216B has a rated short circuit breaking capacity of 10kA.

    Q: What type of protection does this RCBO provide?
    A: It provides both overcurrent and residual current protection with a 30mA residual operating current.

    Q: Is this RCBO compliant with international standards?
    A: Yes, it complies with IEC 60898-1 and IEC 61009-1 standards.

    (ADC216B)

    Warranty

    Warranty starts from Invoice Date

    Domestic Use: 2 Year
    Commercial Use: 2 Year
    Warranty Method: Return to Sparky Direct

    Features
    Specification Details
    Model ADC216B
    Number of Protected Poles 1
    Number of Poles 1 P
    Type of Pole 1 P
    Fixing Mode DIN rail type O (symmetrical)
    Curve C
    Number of Modules 1
    Rated Short Circuit Breaking Capacity Icn AC 10 kA
    Rated Operational Voltage Ue 230 / 240 V
    Type of Supply Voltage AC
    Frequency 50/60 Hz
    Rated Insulation Voltage 250 V
    Rated Impulse Withstand Voltage 4000 V
    Rated Residual Operating Current 30 mA
    Rated Current 16 A
    Withstand Not Tripping on 8-20 μs Wave 0.25 kA
    Breaking and Opening Capacity 6000 A
    Min/Max Threshold Value of the AC Thermal Operation 1.13 / 1.45 In
    Magnetic Regulating Current 5 / 10 In
    Electric current / temperature -25°C ~ 70°C
    20.81A ~ 13.6A
    Depth of Installed Product 70 mm
    Height of Installed Product 115 mm
    Width of Installed Product 17.8 mm
    Total Power Loss under IN 4.9 W
    Power Loss per Pole at In 2.6 W
    Electric Endurance in Number of Cycles 2000
    Number of Mechanical Operations 10000
    Type of Top Connection for Modular Devices With screw
    Type of Bottom Rail Clip for Modular Devices Metallic isolated
    Type of Bottom Connection for Modular Devices BIconnect
    Top Removability for Modular Devices No
    Bottom Removability for Modular Devices No
    Suitable for Flush-Mounting Yes
    Connection Cross-Section at Output with Screw (Flexible Conductor) 1 / 16 mm²
    Connection Cross-Section at Output with Screw (Massive Conductor) 1 / 25 mm²
    Connection Cross-Section for Rigid Conductor (Upstream Terminals with Screws) 1 / 16 mm²
    Downstream Cage Clamp Delivery Status Opened
    Upstream Cage Clamp Delivery Status Opened
    Length of Conductors Used for the Heating Test 1 m
    Conductor Cross-Section Used for Heating Test 2.5 mm²
    Type Selective No
    Can be Accessorized No
    With Transparent Product Label Holder Yes
    Standard Text IEC 61009-1
    European Directive WEEE Concerned
    Protection Index IP IP20
    Residual Current Type A
    REACH Conform No
    RoHS Conform Yes
    Halogen Free No
    Operating Temperature -5…40 °C
    Degree of Pollution 2
    Class of Energy Limitation I²t 3
    Altitude 2000 m
    Air Humidity Protection 95% / 55°C
    Storage/Transport Temperature -40…70 °C
    Specifications

    These specifications and characteristics outline physical, mechanical, electrical details.

    Brand Hager Electrical
    SKU ADC216B
    Barcode # 3250611035527
    Package Weight 0.210kg
    Package Width 0.040m
    Package Height 0.080m
    Package Length 0.150m
    TYPE VALUE
    Type Circuit Protection
    Brand Hager Electrical
    Rated Current (A) 16
    Mounting Din Rail
    Voltage (V) 240V
    Number of Poles 1P
    Overcurrent trip characteristic C Curve
    Breaking Capacity 10kA
    Residual Current 30mA
    Curve C
    Rated Voltage 230/240V AC
    Reviews
    0.0

    0 Reviews
    5 STARS
    0
    4 STARS
    0
    3 STARS
    0
    2 STARS
    0
    1 STAR
    0
    Be The First To Review This Product!

    Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

    Write a review

    Related Category Products