        Volt Safety | Low Voltage Switchboard Rescue Kit | 1000V

        The Volt Safety LVR-KIT is a low-voltage rescue kit rated up to 1000V, designed for trained safety observers to assist someone in contact with live LV equipment. Built to meet AS/NZS 4836:2011 standards, the LVR-KIT provides everything needed for safe, rapid response on low-voltage switchboards in Australian workplaces.

        Switchboard rescue work demands immediate, compliant action when a worker comes into contact with live electrical equipment. Unlike generic first-aid kits, the LVR-KIT is purpose-built for low-voltage emergencies, eliminating guesswork and ensuring that every tool meets safety-regulation requirements. Class 0 insulated gloves, a non-conductive crook, fire blanket, and emergency isolation signage work together to protect rescuer and victim alike. The waterproof carry bag doubles as a water bucket for burn treatment, and high-visibility reflective lettering ensures the kit is findable in low-light or blackout conditions.

        Electricians, safety observers, and facilities managers choose the LVR-KIT because it provides a complete, standards-compliant rescue setup at a single grab point. No assembly required, no missing components, no improvisation. The kit is stored near the switchboard or with the designated safety observer, ready to deploy in seconds. Every six months, a quick check of gloves, batteries, dressing, and bag integrity ensures readiness without the cost and complexity of managing individual components.

        Features

        • Complies with AS/NZS 4836:2011 — the Australian standard for safe work on low-voltage switchboards, covering rescue tools, PPE, and emergency procedures for licensed electrical work.
        • Class 0 insulated gloves (1000V-rated) — Size 11 universal fit, marked "Rescue Only" to prevent accidental use in routine work and ensure they remain reserved for emergency response.
        • Non-conductive insulated crook — safely pulls someone away from live contact without risk of electrocution to the rescuer, tested and rated for LV duty.
        • Waterproof, reflective rescue bag — heavy-duty carrying case with day-night high-visibility lettering for fast location in dark conditions, and doubles as a water bucket for emergency burns treatment.
        • Fire blanket (AS/NZS 3504, 1.8m x 1.2m) — for smothering electrical fires or wrapping burns injuries during transport or initial care.
        • Multi-trauma burns dressing — sterile, ready-to-use dressing for immediate first aid on electrical burn injuries.
        • LED torch with batteries — non-conductive, waterproof torch for visibility in dark switchboard rooms or during blackout emergencies.
        • Emergency isolation sign — printed, laminated "Isolate Here in Emergency" sign with string attachment for clear indication of the isolation point.
        • First-aid quick-reference booklet — portable guide to assist trained safety observers and rescuers through emergency response steps on site.
        • Designed for licensed work only — not for general electrical work or untrained use; the kit assumes rescuer competence and compliance with AS/NZS 4836 training requirements.

        Where to use

        • Fault-finding on live 230–240V switchboards — where trained safety observers must be present and equipped to respond to accidental contact with live parts during isolation or testing work.
        • Utilities and network provider depots — facilities managing LV distribution equipment where rescue readiness is a regulatory requirement and staff must have immediate access to compliant kits.
        • Facilities with on-site electrical switchboards — multi-unit residential, commercial, or industrial buildings where a designated safety observer holds the kit near the main or distribution board.
        • Emergency services and transport depots — public transport, emergency response, and utility maintenance teams performing live-work or standby rescue on LV equipment.
        • Training and competency verification — used in AS/NZS 4836 rescue training courses to familiarise licensed electricians and observers with standard-compliant tools.
        • Workplace safety audits — meets audit and compliance requirements for organisations working on or near live electrical switchboards.
        • Standby safety observer stations — deployed near switchboards in workshops, electrical depots, and industrial facilities where a trained observer must be immediately available.

        The Volt Safety LVR-KIT is not suitable for high-voltage work, outdoor exposed locations, or untrained personnel. It is designed exclusively for low-voltage rescue by workers who have completed AS/NZS 4836 training and hold current competency certification.

        Verified Sparky Direct customer reviews: Volt Safety LVR-KIT (LVR-KIT)

        "Great quality product at a great price." — Sue

        "Good quality product, received on time and in good condition." — David

        "Great product, essential for the electrical trade." — Sue

        (LVR-KIT)

        It is a low-voltage switchboard rescue kit used by a trained safety observer to safely assist someone in contact with a live LV source, rated up to 1 kV.

        It aligns with AS 4836 for safe work on LV equipment, AS/NZS IEC 60903 for insulated gloves (Class 0), and AS/NZS 3504 for the fire blanket.

        A waterproof rescue bag, Class 0 insulated rescue gloves, insulated crook/hook, emergency isolation sign, trauma dressing, LED torch with batteries, fire blanket, and a basic first-aid booklet.

        Yes. Sparky Direct lists the LVR-KIT as compliant for typical LV rescue requirements in Australia.

        It saves time and removes guesswork. It includes all key items needed for LV rescue and meets typical safety expectations.

        Keep it close to the switchboard or with the safety observer so it is easy to reach during an emergency.

        Every 6 months or sooner if used. Check gloves, blanket, torch batteries, dressings, and bag condition.

        Yes. It doubles as a water bucket, useful for cooling burns or carrying water during an emergency.

        The LVR-KIT is a low-voltage rescue kit rated up to 1000V, designed for trained safety observers to assist someone in contact with live LV equipment. It is for licensed electricians, facilities managers, and utility workers who have completed AS/NZS 4836 rescue training and hold current competency certification. It is not for general electrical work or untrained personnel.

        The LVR-KIT complies with AS/NZS 4836:2011 (safe work on LV switchboards), AS/NZS IEC 60903 (Class 0 insulated gloves), and AS/NZS 3504 (fire blanket certification). Gloves are rated to 1000V and tested for rescue use.

        The kit includes Class 0 insulated gloves (Size 11), a non-conductive insulated crook, an emergency isolation sign, a multi-trauma burns dressing, a fire blanket (1.8m x 1.2m), an LED torch with batteries, a first-aid quick-reference booklet, and a heavy-duty waterproof carry bag that doubles as a water bucket.

        Unlike generic first-aid kits, the LVR-KIT is purpose-built for low-voltage electrical emergencies. Every item is selected and certified for LV rescue under AS/NZS standards. It includes specialised tools (insulated crook, Class 0 gloves) that a general first-aid kit does not, and it is designed to be deployed by trained safety observers on switchboards, not for injuries in general.

        Check the LVR-KIT every six months or sooner if used. Inspect gloves for damage, verify torch batteries work, check fire blanket condition, inspect dressing packets for damage, and confirm the carry bag is intact and clean. Replace any damaged or expired items immediately.

        Keep the LVR-KIT close to the switchboard or with the designated safety observer so it can be grabbed instantly during an emergency. Mounting near the main switchboard or distribution board is common practice. Do not lock it away or store it in a location that slows access during an emergency.

        No. The LVR-KIT is rated for low-voltage work up to 1000V only. High-voltage rescue requires different equipment and training under different standards (e.g., Class 1, 2, 3, or 4 HV kits for 7.5kV and above). Volt Safety manufactures separate HV rescue kits for higher voltages.

        The Volt Safety LVR-KIT is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 1 Year
        Commercial Use: 1 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Volt Safety
        SKU LVR-KIT
        Package Weight 3.030kg
        TYPE VALUE
        Type Safety Products
        Brand Volt Safety
        Colour Yellow
        Height (mm) 320
        Width (mm) 500
        Depth (mm) 90
        Voltage (V) 1000V

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products