Skip to main content
Free Bugle Box with Order $500+ | Free Shipping $330+ | 3025-VW Price DROP More

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Product Category Suggestions
      Pages

        Learn more by watching our HAGER ADA940T | 40 Amp 2 Pole 6kA | 30mA RCD/MCB RCBO video.

        Hager | ADA RCBO 40A 2 Pole 6kA C Curve | Type A Residual Current

        The Hager ADA940T is a residual current breaker with overcurrent protection (RCBO), rated 40 A on a C curve. It carries 30 mA earth leakage sensitivity and a 6 kA short-circuit breaking capacity. The ADA940T is a 1P+N device: the overcurrent protection sits on the active pole, with the neutral switched alongside it. It runs at 240 V AC, 50 Hz, and complies with IEC 61009-1 and AS/NZS 61009-1.

        At 35 mm wide, the ADA940T takes two modules on the DIN rail. Replacing a failed two-pole device on an existing board calls for a like-for-like width, not a rebuilt row. The 40 A rating covers a single-phase final subcircuit designed to draw up to 40 A. A C curve puts the magnetic trip between five and ten times rated current, which covers the inrush of motor and appliance loads.

        The top terminal on the ADA940T is aligned for modular busbar connection, so it lands in a row beside other Hager modular devices. Both the earth leakage and the overcurrent function sit in the one device, so a single part number covers protection on that circuit. It complies with IEC 61009-1 and AS/NZS 61009-1.

        Features

        • 40 A rated current — the ADA940T carries up to 40 A on a single-phase final subcircuit.
        • C curve tripping — the magnetic trip sits between five and ten times rated current, which holds through inrush from motor and appliance loads.
        • 30 mA earth leakage sensitivity — residual current above 30 mA trips the device and opens the circuit.
        • Type A residual current — the ADA940T detects AC residual current and the pulsating DC leakage that electronic loads put on a circuit.
        • 6 kA breaking capacity — rated short-circuit breaking capacity is 6 kA under IEC 60898-1 at 240 V AC.
        • 1P+N configuration — the two poles switch together, so the active and the neutral are both opened at the board.
        • Overcurrent on the active only — one pole is protected against overcurrent; the neutral pole switches with it but is not itself protected.
        • 35 mm installed width — the ADA940T takes two standard modules of rail space in the board.
        • DIN rail mounting — the device clips directly onto standard DIN rail in a switchboard or sub-board.
        • Screw terminals — the terminals take rigid conductor up to 25mm² at the line and load ends.
        • 2.1 Nm terminal torque — screw terminals are tightened to 2.1 Nm when the conductors are landed.
        • IP20 protection — the ADA940T is not weatherproof, so it mounts inside a switchboard or enclosure rather than an exposed position.

        Where to use

        • 40 A single-phase circuits — the ADA940T suits a final subcircuit designed to draw up to 40 A at 240 V.
        • Circuits that switch the neutral — the 1P+N arrangement opens the active and the neutral together at the board.
        • DIN rail switchboards and sub-boards — the ADA940T clips onto standard rail in domestic and commercial boards.
        • Circuits specified for 30 mA — the 30 mA sensitivity covers final subcircuits where earth leakage protection is called up in the design.
        • Circuits feeding electronic loads — Type A detection on the ADA940T covers pulsating DC leakage from appliances with switch-mode supplies and electronic controls.
        • Motor, appliance and control circuits — single-phase circuits protecting motors, appliances and control equipment sit within the device's design intent.
        • Boards within 6 kA — the 6 kA breaking capacity covers residential and commercial switchboards at that prospective fault current.

        The ADA940T detects AC and pulsating DC residual current, and is not suitable for circuits where smooth DC leakage can occur. At IP20 it is not weatherproof and mounts inside a switchboard or enclosure. It is rated to 240 V and to an ambient of 40°C, so it does not suit line-to-line 415 V connection or positions that run hotter.

        Verified Sparky Direct customer reviews: Hager ADA940T 40 Amp 2 Pole 6kA 30mA RCD/MCB RCBO (ADA940T)

        "high quality item, super fast shipping - well packaged / protected" — Duncan

        "Great product price" — Guy

        (ADA940T)

        The ADA940T is an RCBO, so it combines earth leakage detection and overcurrent protection in one device. It trips on residual current above 30 mA and on overcurrent beyond its 40 A rating. It is a 1P+N unit, two modules wide, for 240 V single-phase circuits.

        Type A detection picks up pulsating DC residual current as well as AC. Appliances with switch-mode power supplies and electronic controls can put pulsating DC leakage on a circuit, and a Type AC device does not see it. The ADA940T is a Type A device.

        The ADA940T is 35 mm wide, which is two standard modules on the DIN rail. Installed, it stands 83 mm high and 68 mm deep. It clips onto standard DIN rail, and the top terminal is aligned for modular busbar connection.

        On the ADA940T the overcurrent protection sits on the active pole only. The neutral pole switches with the active, so both conductors are opened when the device trips or is switched off. The neutral itself is not protected against overcurrent.

        The screw terminals take rigid conductor up to 25mm², or flexible conductor up to 16mm². Tighten them to 2.1 Nm. Both the line and load terminals are screw type, and the neutral sits on the right-hand side of the device.

        A Type A device covers AC and pulsating DC residual current, not smooth DC. Circuits that can produce smooth DC leakage sit outside what the ADA940T detects. It is also IP20, so it belongs inside a switchboard or enclosure, and it is rated to 240 V with a 40°C ambient limit.

        Two years for domestic use and two years for commercial use, both running from the invoice date. The warranty method is return to Sparky Direct. Warranty is void if the product is not installed by a licensed electrician. A 100-day money-back guarantee also applies to unused items in original packaging.

        The Hager ADA940T is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Hager Electrical
        SKU ADA940T
        Model # ADA940T
        Barcode # 3250611011644
        Package Weight 0.250kg
        TYPE VALUE
        Type Circuit Protection
        Brand Hager Electrical
        Range ADA
        Rated Current (A) 40
        Height (mm) 83
        Width (mm) 35
        Depth (mm) 68
        Standards AS/NZ 61009-1
        Mounting DIN rail
        Voltage (V) 240
        Number of Poles 2
        IP Rating IP20 ( IP40 Enclosed )
        Breaking Capacity 6kA
        Neutral Position Right
        Earth Leakage Sensitivity 30mA
        Earth Leakage Protection Class Type A
        Curve C

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products