The Electra-Cables 7-170-1R is a 16mm² single double insulated cable supplied on a 100-metre drum. Red core with white sheath. Suitable for fixed wiring in sub-circuits carrying moderate current loads where a single insulated conductor meets the circuit design.
Single double insulated cable (SDI) combines a single conductor inside two layers of insulation, making it suitable for temporary installations, sub-circuits, and fixed wiring where extra protection is needed. The 16mm² cross-section handles higher current capacity than smaller gauges and is commonly used for final sub-circuit runs in residential and light commercial work. Red core identifies the active phase conductor.
The 100-metre drum format suits electricians stocking SDI cable for repeat jobs and site work. Cable can be cut to length as needed. Complies with the wiring rules for single core insulated cables. No moisture barrier, so ensure runs are in dry locations or appropriately conditioned environments. Check compatibility with the final load, circuit protection, and installation method before ordering.
Not suitable for wet locations or high-moisture environments without additional protection. Check local wiring rules and circuit protection requirements before installation. Ensure the 16mm² gauge matches the circuit load and overcurrent protection device rating.
(7-170-1R)
Cable gauge depends on the circuit load, protection device rating, and run distance. The 7-170-1R at 16mm² suits moderate-load final sub-circuits. For loads above 32A or longer runs, consult the wiring rules and verify the protection rating matches the cable capacity.
Yes. The cable can be trimmed to fit specific run distances on site. Seal cut ends appropriately to prevent moisture ingress, and ensure termination meets the applicable wiring standard.
SDI cable on its own is not suitable for wet or outdoor locations. If outdoor use is required, run the cable through conduit or ducting to protect the insulation. Check local regulations for outdoor circuit requirements.
Red identifies the active phase conductor in single-phase and three-phase circuits. Use it for the phase leg of a final sub-circuit, not the neutral or earth.
Single double insulated cable has one conductor inside two insulation layers. It is suitable for fixed sub-circuits and temporary installations. For multi-core runs or outdoor use, consider TPS flat, building wire, or orange circular cable. The choice depends on the circuit design and environment.
The cable meets the requirements for single core insulated cable under AS/NZS 3008. Confirm compliance with your specific installation method, load rating, and environmental conditions before use.
The Electra-Cables 7-170-1R is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.
100-Day Fuss-Free Returns
We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.
If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.
All products come with a manufacturer’s or supplier’s warranty
Damaged or Faulty Goods
If your order arrives damaged or is faulty, let us know within 24 hours.
Contact us via our chat to arrange the return.
Exclusions
We can’t accept returns for:
How to Request a Return
Warranty starts from Invoice Date
Domestic Use: 1 Year
Commercial Use: 1 Year
Warranty Method: Return to Sparky Direct
These specifications and characteristics outline physical, mechanical, electrical details.
| Brand | Electra-Cables |
| SKU | 7-170-1R |
| Package Weight | 23.350kg |
| TYPE | VALUE |
|---|---|
| Brand | Electra-Cables |
| Cable Length (m) | 100 |
| Cable Size (mm²) | 16 |
| Sheath Colour | White |
| Core Colour | Red |
Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.
Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.
Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.
Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.
For website terms and conditions https://www.sparkydirect.com.au/terms-of-use
Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.