Search Results:
Search Results:
Search Results:
Search Results:
Learn more by watching our HAGER ADC910T | 10Amp 6 kA Single Pole RCBO video.
The Hager ADC910T is a single pole residual current breaker with overcurrent protection (RCBO) rated 10A 240V, with 30mA Type A sensitivity and a 6kA breaking capacity. Designed for DIN rail installation in domestic switchboards and load centres, the ADC910T complies with AS/NZS 61009-1 and provides combined earth leakage and overcurrent protection in a single 1-module footprint.
Switchboard space is often constrained in retrofit and renovation work. The ADC910T saves space with reduced height compared to older two-pole designs, allowing up to 20% extra wiring clearance in Golf-style enclosures. Licensed electricians value the slimline form factor because it gives them more room to work within the board without sacrificing protection. The pre-installed neutral flying lead eliminates one cable connection, cutting install time on the job and reducing the risk of wiring errors on site.
The ADC910T is designed for ease of installation and professional reliability. Bi-connect terminals accept cables directly or interface with Hager fork busbars, giving you flexibility in how you wire the board. Fast insulation resistance testing means you can verify the installation without disconnecting outgoing circuits. For job sites requiring flexibility — construction boards, temporary installations, caravans, motorhomes, or solar PV systems — the switched neutral design supports non-standard wiring schemes without extra modules. Single-module design makes the ADC910T a direct replacement for old MCBs when upgrading protection.
The ADC910T is designed for standard residential and light commercial circuits. It is not suitable for circuits protected by a different RCD type (e.g. where Type B or Type F protection is mandated), circuits requiring 100mA sensitivity, or heavy industrial applications. Always consult the Wiring Rules (AS/NZS 3000) and manufacturer instructions to confirm the right protection device for your application.
Verified Sparky Direct customer reviews: Hager ADC910T (ADC910T)
"One of my go to rcbos. Always happy with them." — Corey
"Quick and easy to install, neutral tail is a good length." — Alan
"Small and compact that save space when retrofitting existing boards." — Paul T
(ADC910T)
Yes. The ADC910T is a residual current breaker with overcurrent protection (RCBO), which means it combines two functions in one module. It detects earth leakage faults (residual current) and trips immediately, and it also detects overcurrent (short circuit or overload) and interrupts the circuit to prevent equipment damage and fire risk. You do not need a separate RCD and MCB.
The ADC910T is newer generation (single module) compared to the older two-pole ADC3 series. The key differences are: the ADC910T has a reduced height, saving up to 20% more wiring space in switchboards; it has a pre-installed neutral flying lead (about one metre long), so you have one less cable to terminate; it supports switched neutral applications; and it fits perfectly into Hager's onekonekt system. Electrically and functionally, it provides the same protection as the older design, so it is a direct replacement for modernising older boards.
Installation of the ADC910T must be done by a licensed electrician in accordance with the Wiring Rules (AS/NZS 3000) and local electrical regulations. The RCBO carries voltage and must be installed by a qualified professional to ensure safety and compliance.
The ADC910T is rated for domestic general-purpose circuits up to 10A on 240V, suitable for lighting circuits, power circuits, and mixed general power distribution. It is not suitable for circuits that require Type B or Type F residual current protection (e.g., circuits with frequency-controlled equipment, industrial machinery, or large variable-speed motors). Always confirm the correct protection type with the circuit designer and the Wiring Rules.
The Hager ADC910T carries a 2-year manufacturer's warranty on domestic use (2 years on commercial use) from the date of invoice. Warranty covers manufacturing defects and requires return to Sparky Direct for assessment. Warranties are void if the device is installed by someone other than a licensed electrician or is modified. In-home warranty repair services may be available through authorised Hager service partners depending on the region.
100-Day Fuss-Free Returns
We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.
If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.
All products come with a manufacturer’s or supplier’s warranty
Damaged or Faulty Goods
If your order arrives damaged or is faulty, let us know within 24 hours.
Contact us via our chat to arrange the return.
Exclusions
We can’t accept returns for:
How to Request a Return
Warranty starts from Invoice Date
Domestic Use: 2 Year
Commercial Use: 2 Year
Warranty Method: Return to Sparky Direct
These specifications and characteristics outline physical, mechanical, electrical details.
| Brand | Hager Electrical |
| SKU | ADC910T |
| Model # | ADC910T |
| Barcode # | 3250611033332 |
| Package Weight | 0.160kg |
| TYPE | VALUE |
|---|---|
| Type | Circuit Protection |
| Brand | Hager Electrical |
| Rated Current (A) | 10 |
| Height (mm) | 85 |
| Width (mm) | 18 |
| Depth (mm) | 77 |
| Standards | AS/NZ 61009-1 |
| Mounting | Din Rail |
| Curve | C |
| Voltage (V) | 240V |
| Earth Leakage Protection Class | Type A |
| Earth Leakage Sensitivity | 30mA |
| Box increments (This item is sold individually) | 54 |
| Residual Current | 30mA |
| Breaking Capacity | 6kA |
| Overcurrent trip characteristic | C Curve |
| Earth Fault Wave Form | Type A |
| IP Rating | IP20 ( IP40 Enclosed ) |
| Number of Poles | 1P+N |
Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.
Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.
Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.
Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.
For website terms and conditions https://www.sparkydirect.com.au/terms-of-use
Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.