Skip to main content
$75 Prezzee Back on Clipsal Orders $750+ | FREE Standard Delivery on Clipsal Orders Over $330 More

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Product Category Suggestions
      Pages

        Learn more by watching our HAGER ADC910T | 10Amp 6 kA Single Pole RCBO video.

        Hager ADC910T | Single Pole RCBO 10A 6 kA 240V Type A | 1P+N 30mA C Curve

        The Hager ADC910T is a single pole residual current breaker with overcurrent protection (RCBO) rated 10A 240V, with 30mA Type A sensitivity and a 6kA breaking capacity. Designed for DIN rail installation in domestic switchboards and load centres, the ADC910T complies with AS/NZS 61009-1 and provides combined earth leakage and overcurrent protection in a single 1-module footprint.

        Switchboard space is often constrained in retrofit and renovation work. The ADC910T saves space with reduced height compared to older two-pole designs, allowing up to 20% extra wiring clearance in Golf-style enclosures. Licensed electricians value the slimline form factor because it gives them more room to work within the board without sacrificing protection. The pre-installed neutral flying lead eliminates one cable connection, cutting install time on the job and reducing the risk of wiring errors on site.

        The ADC910T is designed for ease of installation and professional reliability. Bi-connect terminals accept cables directly or interface with Hager fork busbars, giving you flexibility in how you wire the board. Fast insulation resistance testing means you can verify the installation without disconnecting outgoing circuits. For job sites requiring flexibility — construction boards, temporary installations, caravans, motorhomes, or solar PV systems — the switched neutral design supports non-standard wiring schemes without extra modules. Single-module design makes the ADC910T a direct replacement for old MCBs when upgrading protection.

        Features

        • Slimline 1P+N RCBO — combines earth leakage and overcurrent protection in one module, occupying the space of a single circuit breaker in the switchboard.
        • Reduced height design — fits DIN rail enclosures and provides up to 20% extra wiring space compared to older two-pole designs, easing installation in tight boards.
        • Pre-installed neutral flying lead — one metre long neutral tail reduces cable terminations on site and cuts installation time.
        • Bi-connect terminals — accept supply from either direct cable connections in the terminal cage or from Hager fork busbars in the slot, providing full flexibility on board layout.
        • C-curve overcurrent characteristic — suits standard domestic circuits with resistive loads and moderate inrush currents, typical in lighting and general power circuits.
        • Type A residual current protection — responds to AC and pulsating DC fault currents, suitable for circuits with modern switching-mode power supplies and electronic equipment.
        • Electrically bi-directional — can be fed from either direction without re-termination, useful for complex board configurations and upgrades.
        • Fast insulation resistance testing — insulation test can be performed without disconnecting outgoing circuit wires, saving time during commissioning.
        • Built-in fault trip indicator — visual confirmation of the reason for a trip (earth leakage or overcurrent), helping diagnose circuit faults.
        • Switched neutral functionality — breaks both active and neutral simultaneously, essential for temporary installations, construction sites, caravans, solar PV systems, and EV charging stations.
        • 6kA short-circuit rating — provides full protection in domestic and light commercial installations up to the 6kA breaking capacity limit of AS/NZS 61009-1.
        • DIN rail mount — standard mounting for modular switchboards and distribution boards; works with Hager Invicta and onekonekt systems.

        Where to use

        • Domestic switchboard upgrades — replaces ageing two-pole RCBO designs with space-saving single-module protection; ideal when board congestion limits room for larger breakers.
        • New domestic installations — standard protection for new builds, extensions, and major renovations where modern electronic loads require Type A residual current sensitivity.
        • Light commercial circuits — suitable for small commercial boards protecting office lighting, power distribution, and equipment circuits up to 10A.
        • Renovation and retrofit work — compact footprint allows circuit protection upgrades in existing boards without requiring a full board replacement.
        • Construction site temporary boards — switched neutral design supports temporary switchboards and construction power distribution systems.
        • Transportable structures — caravans, motorhomes, demountable buildings, and show installations benefit from the switched neutral configuration.
        • Solar PV installations — Type A protection with switched neutral capability suits residential solar systems where DC fault protection is managed by the inverter.
        • EV charging circuits — provides base-level earth leakage protection for electric vehicle charging points; confirm total system protection strategy with system designer.

        The ADC910T is designed for standard residential and light commercial circuits. It is not suitable for circuits protected by a different RCD type (e.g. where Type B or Type F protection is mandated), circuits requiring 100mA sensitivity, or heavy industrial applications. Always consult the Wiring Rules (AS/NZS 3000) and manufacturer instructions to confirm the right protection device for your application.

        Verified Sparky Direct customer reviews: Hager ADC910T (ADC910T)

        "One of my go to rcbos. Always happy with them." — Corey

        "Quick and easy to install, neutral tail is a good length." — Alan

        "Small and compact that save space when retrofitting existing boards." — Paul T

        (ADC910T)

        Yes. The ADC910T is a residual current breaker with overcurrent protection (RCBO), which means it combines two functions in one module. It detects earth leakage faults (residual current) and trips immediately, and it also detects overcurrent (short circuit or overload) and interrupts the circuit to prevent equipment damage and fire risk. You do not need a separate RCD and MCB.

        The ADC910T is newer generation (single module) compared to the older two-pole ADC3 series. The key differences are: the ADC910T has a reduced height, saving up to 20% more wiring space in switchboards; it has a pre-installed neutral flying lead (about one metre long), so you have one less cable to terminate; it supports switched neutral applications; and it fits perfectly into Hager's onekonekt system. Electrically and functionally, it provides the same protection as the older design, so it is a direct replacement for modernising older boards.

        Installation of the ADC910T must be done by a licensed electrician in accordance with the Wiring Rules (AS/NZS 3000) and local electrical regulations. The RCBO carries voltage and must be installed by a qualified professional to ensure safety and compliance.

        The ADC910T is rated for domestic general-purpose circuits up to 10A on 240V, suitable for lighting circuits, power circuits, and mixed general power distribution. It is not suitable for circuits that require Type B or Type F residual current protection (e.g., circuits with frequency-controlled equipment, industrial machinery, or large variable-speed motors). Always confirm the correct protection type with the circuit designer and the Wiring Rules.

        The Hager ADC910T carries a 2-year manufacturer's warranty on domestic use (2 years on commercial use) from the date of invoice. Warranty covers manufacturing defects and requires return to Sparky Direct for assessment. Warranties are void if the device is installed by someone other than a licensed electrician or is modified. In-home warranty repair services may be available through authorised Hager service partners depending on the region.

        The Hager ADC910T is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Hager Electrical
        SKU ADC910T
        Model # ADC910T
        Barcode # 3250611033332
        Package Weight 0.160kg
        TYPE VALUE
        Type Circuit Protection
        Brand Hager Electrical
        Rated Current (A) 10
        Height (mm) 85
        Width (mm) 18
        Depth (mm) 77
        Standards AS/NZ 61009-1
        Mounting Din Rail
        Curve C
        Voltage (V) 240V
        Earth Leakage Protection Class Type A
        Earth Leakage Sensitivity 30mA
        Box increments (This item is sold individually) 54
        Residual Current 30mA
        Breaking Capacity 6kA
        Overcurrent trip characteristic C Curve
        Earth Fault Wave Form Type A
        IP Rating IP20 ( IP40 Enclosed )
        Number of Poles 1P+N

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products