        Stronglink | Cat 6A Patch Lead 2m F/UTP Shielded | Blue LSZH

        The Stronglink STKPLC6A2 is a 2 metre Category 6A patch lead, built from 4 pair F/UTP shielded cable with factory terminated RJ45 plugs at both ends. The STKPLC6A2 carries a blue LSZH jacket and is specified for 10GBase-T channel performance. It is made to ISO/IEC 11801 and AS/NZS 3080, is RoHS compliant and UL listed, and is tested to AS/CA S008 by a NATA accredited laboratory.

        Two metres is the length most work areas need once the outlet sits behind a desk return or under a bench. It also covers a full height rack from a top mounted panel down to a switch several units below, without joining two shorter cords through a coupler and adding a failure point. Screened cabling systems surrender their advantage at the patch cord, where an unscreened lead undoes the continuity established on the permanent horizontal run. The overall foil screen continues the full length of the STKPLC6A2 and terminates inside the RJ45 connector at either end.

        Data work is priced on labour hours, and factory terminated cords remove the slowest step in the sequence. Every STKPLC6A2 arrives pre-tested and booted, so there is no field crimping and no connector to re-terminate when a link fails certification. The slimline profile and anti-snag boot keep two metre cords manageable in a dense patch field, where thicker leads bunch at the panel and catch on adjacent latches. Stocking two metre leads in blue maintains colour coded patching conventions throughout a communications room and out to the work area.

        Features

        • Category 6A performance — designed to deliver channel performance across 10GBase-T applications when patched into a compliant Class EA channel.
        • 4 pair F/UTP construction — an overall foil screen wraps all four twisted pairs, carrying the screening of the fixed cabling through the patch cord.
        • LSZH jacket — low smoke zero halogen sheathing produces less smoke and no halogen gas when exposed to fire.
        • Factory terminated — the STKPLC6A2 ships with both RJ45 plugs fitted and tested, so there is no field termination step.
        • Anti-snag boots — moulded boots cover the latch so cords pull clear of dense patch fields without catching or shearing the clip.
        • Slimline footprint — a reduced outside diameter keeps cord management workable in both rack and field environments.
        • Open outlet compatibility — works with RJ45 outlet products from any manufacturer, provided those outlets comply with the relevant industry standards.
        • ISO/IEC 11801 and AS/NZS 3080 — built to the international and Australian structured cabling standards for Class EA channels.
        • AS/CA S008 tested — verified by a NATA accredited test laboratory against the Australian customer cabling requirements.
        • RoHS and UL — the STKPLC6A2 meets RoHS restrictions on hazardous substances and carries UL listing.
        • Blue jacket — supports colour coded patching schemes where cord colour marks the service, VLAN, or floor.
        • Fixed 2 metre length — the cord cannot be shortened, extended, or re-terminated on site, so the length is chosen at order time.

        Where to use

        • Outlet to workstation — the STKPLC6A2 reaches from a wall or floor outlet to a desktop machine, dock, or IP phone across a standard desk.
        • Full height rack patching — links a panel at the top of a rack to a switch mounted well below it, with no coupler in the channel.
        • 10GBase-T switch and server ports — patches copper 10 gigabit links in data cabinets where the fixed cabling is already Class EA.
        • Screened cabling systems — the F/UTP build suits sites specified as shielded end to end, including plant rooms and areas with heavy electrical noise.
        • Access points and ceiling devices — the STKPLC6A2 covers the drop from a ceiling outlet to an access point or camera mounted nearby.
        • Office fit-outs and floor distributors — feeds edge switches and work area outlets during commercial fit-out and refresh work.
        • Occupied buildings with LSZH specifications — schools, hospitals, and public buildings that call up low smoke zero halogen cable in patching and work areas.
        • Moves, adds, and changes — a stocked two metre cord covers most repatching without cutting a new lead to length.

        The STKPLC6A2 is a factory terminated patch cord and is not intended for use as fixed horizontal cabling. It cannot be punched down to an outlet or a patch panel, and the plugs cannot be removed and refitted on site. Patch cord length counts against the total channel length allowed under the cabling standard, so account for cords at both ends when the fixed run is already long.

        (STKPLC6A2)

        The foil screen carries through a channel where the outlets and patch panels at each end are also shielded, and where the screen is bonded to earth as the cabling system manufacturer specifies. Plugged into unshielded outlets, the cord still passes data, but the screening path stops at the plug.

        No tools are needed. The cord is factory terminated with an RJ45 plug at each end and tested before packing, so it plugs straight into a patch panel port, outlet, or switch port. Fitting is limited to seating each plug until the latch clicks.

        Stronglink Cat 6A patch cords work with RJ45 outlet products from any manufacturer, provided those outlets comply with the relevant industry cabling standards. Mixing brands within a channel is acceptable where every component is rated for Category 6A or Class EA performance.

        The RJ45 plug uses the same 8P8C interface as Cat 5e and Cat 6 ports, so the cord plugs into older switches, outlets, and network cards. Performance across any channel is set by its lowest rated component, so a Cat 6A cord will not lift a Cat 5e link past Cat 5e.

        F/UTP describes the shielding. A single foil screen wraps all four twisted pairs, while the pairs themselves are unscreened. The foil gives the cord protection against outside electrical noise and carries the screening of a shielded fixed cabling system through the patch field.

        Patch cords at both ends count towards the total channel length permitted under the cabling standard, alongside the fixed horizontal run. On a long horizontal run, two metre cords at each end reduce the headroom available, which is why cord length is worth checking before a channel is certified.

        LSZH stands for low smoke zero halogen. Under fire conditions the sheath gives off less smoke and no halogen gas, which matters in occupied buildings, escape routes, and comms rooms. Many commercial and public sector specifications call up LSZH cable in patching areas for that reason.

        No. The STKPLC6A2 is a factory terminated stranded patch cord supplied at a fixed 2 metre length. The plugs are not field removable and the cord is not punched down to an outlet or patch panel, so the correct length is selected at order time.

        The Stronglink STKPLC6A2 is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 1 Year
        Commercial Use: 1 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Stronglink
        SKU STKPLC6A2
        Model # STKPLC6A2
        Barcode # 9337376005768
        Package Weight 0.030kg
        TYPE VALUE
        Type Patch Lead
        Brand Stronglink
        Colour Blue
        Category Type 6A
        Length (m) 2

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products