        Major Tech | Non-Contact Infrared Body Thermometer 32-42.5°C | ±0.2°C Accuracy 1-10cm Range

        The Major Tech MT688 is a non-contact infrared thermometer designed to read body surface and forehead temperature on infants and adults from 1cm to 10cm away. Body mode covers 32°C to 42.5°C and surface mode covers 0°C to 60°C, both to a stated accuracy of ±0.2°C with 0.1°C resolution. Surface mode suits baby bottles, bath water, and room temperature checks, giving the MT688 a second job beyond the first-aid kit. Readings appear in under a second on a backlit LCD, with the last 32 measurements stored in memory.

        Checking a temperature with a contact thermometer means waking a sleeping child or passing a shared probe between employees in a workplace first-aid room. A slow instrument compounds the difficulty, particularly with an unwell infant who refuses to hold still for a conventional under-arm reading. The MT688 completes its measurement from 1cm to 10cm away in under a second, without any contact against the skin. A settable alarm value identifies readings above the configured threshold immediately, removing subjective judgement from a rapid screen.

        For an electrical contractor stocking site first-aid stations, the MT688 adds a hygienic screening tool that complies with IEC 60601-1 medical electrical safety and IEC 60601-1-2 EMC requirements. The same instrument doubles as a rapid surface reader, with digitally adjustable emissivity from 0.10 to 1.0 for evaluating a bottle, a bath, or an ambient room measurement. It operates on two AAA cells, and automatic power off after several seconds of inactivity conserves battery capacity between uses. At 130 grams and 131mm in length, the unit stores in a glovebox or first-aid pouch without a dedicated case.

        Features

        • Non-contact measurement — the MT688 reads forehead and body surface temperature from 1cm to 10cm away, with nothing touching the skin.
        • Body mode 32°C to 42.5°C — stated accuracy of ±0.2°C with 0.1°C resolution covers the full screening range for infants and adults.
        • Surface mode 0°C to 60°C — the same ±0.2°C accuracy applies to baby bottles, bath water, and room temperature readings.
        • Response under 1 second — readings land fast enough to check a moving infant or a queue of workers without a hold-up.
        • Settable alarm value — the MT688 signals when a reading exceeds the threshold you set, taking interpretation out of a quick screen.
        • 32-reading memory — recall the last 32 measurements on screen to track a temperature over hours without writing anything down.
        • Adjustable emissivity — digital adjustment from 0.10 to 1.0 tunes surface mode to different materials for truer readings.
        • Backlit LCD — the display stays readable in a dim bedroom or a plant room without a torch.
        • °C or °F selectable — switch units to match site paperwork or personal preference.
        • Automatic data hold and auto power off — the last reading holds on screen, and the MT688 shuts down after several seconds idle to save its two AAA batteries.
        • Medical electrical compliance — designed to IEC 60601-1 safety and IEC 60601-1-2 EMC requirements for medical electrical equipment.
        • Purpose-built ranges — the 60°C surface ceiling rules out hot pipework and cooking checks; a general-purpose infrared thermometer covers those jobs.

        Where to use

        • Site and workshop first-aid stations — the MT688 gives a hygienic, no-contact way to screen a temperature before deciding on next steps.
        • Family use at home — forehead checks on sleeping infants and adults without waking anyone or washing a probe between readings.
        • Baby bottle and bath water checks — surface mode confirms a comfortable temperature before feeding or bathing.
        • Room and ambient checks — spot-read nurseries, offices, and server or plant rooms where comfort or storage conditions matter.
        • Office and reception screening — the MT688 supports quick, repeatable temperature checks with its alarm threshold and 32-reading memory.
        • HVAC comfort call-outs — a fast ambient figure at handover backs up thermostat settings with a measured number.

        The MT688 is a screening tool, and a reading is not a medical diagnosis; confirm any concerning result with a clinical thermometer and seek medical advice where needed. Body mode reads only between 32°C and 42.5°C, and surface mode is capped at 60°C, so hot plant, pipework, and cooking surfaces are outside its range. Operate it within the 1cm to 10cm measuring distance, as readings taken outside that window fall outside the stated accuracy.

        (MT688)

        The stated accuracy is ±0.2°C in both modes, with 0.1°C resolution. Body mode covers 32°C to 42.5°C and surface mode covers 0°C to 60°C, with readings returned in under a second at a measuring distance of 1cm to 10cm.

        Yes. It reads forehead and body surface temperature from 1cm to 10cm away, so nothing contacts the person being checked. That makes it practical for sleeping infants and for screening several people without cleaning a probe between readings.

        No. It is a screening thermometer designed to IEC 60601-1 and IEC 60601-1-2 medical electrical equipment requirements. A high or unusual reading should be confirmed with a clinical thermometer, and medical advice sought where there is any concern.

        Surface mode reads 0°C to 60°C for baby bottles, bath water, and room or ambient temperature. Emissivity adjusts digitally from 0.10 to 1.0 to suit different surfaces. Hotter targets such as pipework or cooking surfaces sit outside its range.

        You set an alarm value, and the unit signals when a reading exceeds it. The last 32 measurements store in memory for recall on the backlit LCD, which suits tracking a temperature over a day or logging a round of workplace checks.

        It runs on two AAA batteries, which are included along with the instruction manual. Automatic data hold keeps the last reading on screen, and auto power off shuts the unit down after several seconds of inactivity to extend battery life.

        The MT688 carries a 2 year warranty for both domestic and commercial use, starting from the invoice date. Lodge a claim by returning the unit to Sparky Direct with proof of purchase and a fault description; it is then forwarded to Major Tech's authorised service centre for assessment. Allow 7 to 14 working days.

        The Major Tech MT688 is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        All Major Tech Meters sold through Sparky Direct are covered by the manufacturer’s warranty. If you believe your meter is faulty or defective, you may request an assessment under this warranty policy.

        How to Lodge a Warranty Claim

        To initiate a warranty claim:

        1. Return to Sparky Direct
          Ship the meter back to Sparky Direct along with:

          • A copy of your proof of purchase
          • A brief description of the issue
          • Your contact details

          Please ensure the unit is securely packaged to prevent damage in transit.

        2. Forwarded for Assessment
          Upon receiving your meter, we will forward it to Major Tech’s authorised service centre for inspection, testing, and calibration.

        Assessment Process

        Major Tech’s service lab will assess the returned unit to determine:

        • Whether the fault is due to a manufacturer’s defect (covered under warranty), or
        • If the issue is the result of user error or no fault is found.

        Outcomes

        • If approved under warranty: The product will be repaired or replaced at no cost to you.
        • If not covered under warranty: The lab may offer repair services, which will be quoted and billed directly to you by the service provider.

        Important Notes

        As Major Tech’s service labs are independent providers, Sparky Direct cannot govern or guarantee turnaround times or any costs incurred for repairs outside of warranty coverage.

        Please allow up to 7-14 working days for the return of your product.

        Accessories

        2 x AAA Batteries
        Instruction Manual

         

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Major Tech
        SKU MT688
        Model # MT688
        Barcode # 6008229033186
        Package Weight 0.130kg
        TYPE VALUE
        Type Thermometer
        Brand Major Tech
        Height (mm) 35
        Width (mm) 82
        Power Source 2 x AAA Batteries
        Length 131

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products