The NLS 30823 is a 32A four-pole RCBO (Residual Current Circuit Breaker with Overcurrent Protection) rated 240V/415V, Type A, for DIN rail mounting in switchboards and distribution boards. The 30823 provides combined protection against residual earth faults and overcurrent conditions in three-phase circuits with neutral. It complies with AS/NZ 61009-1 and is rated for a 6kA breaking capacity, suitable for intermediate-load three-phase installations.
Three-phase switchboards and distribution boards require space-efficient protection that combines earth leakage detection with circuit overcurrent safeguards. The NLS 30823 eliminates the need for separate RCD and circuit breaker devices by housing both functions in a single DIN rail module, reducing switchboard complexity and cutting installation time. Multi-phase circuits on commercial and industrial installations frequently specify RCBOs at 32A to match intermediate load demands and standard modular board layouts.
Electricians and contractors value the NLS 30823 for its practicality and straightforward operation across repair, upgrade, and new-build projects. The 32A rating suits three-phase submains distribution without oversizing, and the Type A earth leakage class detects standard sinusoidal faults within its 30mA sensitivity band. Stock rotation is simple since the 30823 is part of NLS's established RCBO range, with proven field performance and consistent availability through electrical wholesalers.
The NLS 30823 is not suitable for single-phase circuits, outdoor or wet-area installations, or locations where rapid automatic reclosure is required. It is not designed for use in caravan parks, marinas, or splash-zone applications where higher IP ratings are mandatory.
Verified Sparky Direct customer reviews: NLS 30823 | 32Amp 6kA | 4 Pole RCBO | Type A
"Works perfectly. Trips every time. Good value." — Y
"Sturdy and practical, cheap enough too." — Neil
"Great product, great price." — Chris R
(30823)
The NLS 30823 is a four-pole (3P+N) RCBO designed exclusively for three-phase circuits with neutral. It is not suitable for single-phase installations. For single-phase protection, specify a single-pole RCBO such as the NLS 30810 or 30815 series.
The NLS 30823 at 32A sits between the 20A (NLS 30821) and 40A (NLS 30824) variants. The 32A rating suits intermediate three-phase loads on distribution boards; choose 20A for smaller sub-circuits and 40A for heavier loads such as large air conditioning or manufacturing equipment.
Installation of the NLS 30823 must be carried out by a licensed electrician. The device connects to the mains switchboard and requires compliance with AS/NZS 3000 and local electrical standards. Switchboard work is restricted to qualified persons.
Type A means the NLS 30823 detects standard sinusoidal alternating residual currents at its 30mA sensitivity threshold. Type A is the most common earth leakage class for general-purpose installations including homes, offices, shops, and light industrial use. It does not detect DC components or pulsating DC faults (those require Type B devices).
Breaking capacity is the maximum fault current the RCBO can safely interrupt without sustaining damage. The NLS 30823's 6kA rating means it can handle fault currents up to 6000 amps. This suits most domestic and light commercial switchboards; larger industrial installations may require 10kA or higher.
The NLS 30823 should be tested monthly using the integral test button, a simple press-and-release that simulates an earth fault. Annual professional inspection is recommended on commercial and industrial boards. The device itself has no scheduled replacement interval if operation is normal, though some jurisdictions require RCBOs to be replaced every 10–15 years as a precaution.
The NLS 30823 is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.
100-Day Fuss-Free Returns
We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.
If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.
All products come with a manufacturer’s or supplier’s warranty
Damaged or Faulty Goods
If your order arrives damaged or is faulty, let us know within 24 hours.
Contact us via our chat to arrange the return.
Exclusions
We can’t accept returns for:
How to Request a Return
Warranty starts from Invoice Date
Domestic Use: 1 Year
Commercial Use: 1 Year
Warranty Method: Return to Sparky Direct
These specifications and characteristics outline physical, mechanical, electrical details.
| Brand | NATIONAL LIGHT SOURCES |
| SKU | 30823 |
| Model # | 30823NLS |
| Barcode # | 9336700016531 |
| Package Weight | 0.430kg |
| TYPE | VALUE |
|---|---|
| Type | Circuit Protection |
| Brand | National Light Sources |
| Rated Current (A) | 32 |
| Height (mm) | 84 |
| Width (mm) | 71 |
| Depth (mm) | 80 |
| Standards | AS/NZ 61009-1 |
| Mounting | DIN Rail |
| Voltage (V) | 240/415 |
| Number of Poles | 3P+N |
| IP Rating | IP20 ( IP40 Enclosed ) |
| Breaking Capacity | 6kA |
| Box increments (This item is sold individually) | 1 |
| Earth Leakage Sensitivity | 30mA |
| Earth Leakage Protection Class | Type A |
| Curve | C |
Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.
Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.
Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.
Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.
For website terms and conditions https://www.sparkydirect.com.au/terms-of-use
Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.