Skip to main content
Get $15 Prezzee on $150 MAX9 or Clipsal Lighting | FREE Clipsal Shipping $330+ View

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Product Category Suggestions
      Pages

        Hager | 63A 3P+N RCBO 6kA | Type A 30mA

        The Hager ALM463T is a 63A 3P+N RCBO rated 400–415V AC three-phase, combining residual current and overcurrent protection in a compact 3-module device. The ALM463T delivers 6kA breaking capacity with 30mA Type A RCD sensitivity, protecting three-phase loads against leakage faults and overcurrent. It is certified to AS/NZS standards for use in commercial and industrial switchboards requiring both RCD and MCB combined protection.

        Three-phase commercial installations frequently specify RCBOs in high-current switchboards where space is constrained and combined protection is mandated by code. The C-curve tripping characteristic suits standard industrial loads without nuisance tripping on inrush. Pre-wired tails accelerate board termination, reducing installation time on site.

        The ALM463T is specified by switchboard installers for its compact footprint, Type A 30mA protection, and ability to handle the full 63A load on three-phase circuits. The C-curve responds appropriately to typical three-phase motor and heating element circuits, avoiding false trips while maintaining fast fault clearance. Licensed electricians appreciate the 6kA capacity for commercial premises where fault levels can exceed domestic ratings.

        Features

        • 3P+N combined RCBO — merges MCB and RCD protection into a single device, occupying only three DIN rail modules versus five or more if installed separately.
        • 63A rated, C-curve characteristic — suits three-phase industrial loads; avoids nuisance tripping on motor startup or inrush while maintaining fast fault clearance.
        • Type A 30mA RCD sensitivity — detects both AC and rectified DC leakage faults, essential for circuits with variable-frequency drives or switching power supplies.
        • 6kA short-circuit capacity — safely handles high fault currents typical in commercial switchboards; complies with AS/NZS requirements.
        • Pre-wired tails included — factory-terminated incoming and outgoing conductors reduce board assembly time and connection risk.
        • DIN rail mounted — standard 35mm rail spacing; terminals accept 1–25 mm² solid or 1–16 mm² flexible conductors without additional lugs.
        • Low heat dissipation — 31W power loss at rated current minimises board temperature rise in high-density installations.
        • Wide operating range — rated –5 to 70°C, providing thermal stability across Australian seasonal temperatures.
        • IP20 sealed design — protected against dust and accidental finger contact; suitable for enclosed switchboard environments only.
        • AS/NZS certified — approved for domestic, commercial, and light industrial installations compliant with the Wiring Rules.
        • Not suitable for damp or outdoor locations — IP20 rating does not cover splash zones, wet areas, or installations subject to condensation.

        Where to use

        • Commercial three-phase installations — the ALM463T protects high-current three-phase circuits in office buildings, shopping centres, warehouses, and factories.
        • Industrial switchboards with space constraints — compact 3-module design allows RCBO protection in boards where individual MCB + RCD combinations would occupy more space.
        • Distribution boards serving variable-frequency drives and electronic equipment — Type A sensitivity detects leakage from switched-mode power supplies and VFD fault conditions that Type AC (older) RCDs would miss.
        • Three-phase motor and heating circuits — C-curve profile suits pump motors, compressors, heaters, and other industrial loads without false tripping.
        • Retrofit of older single-RCBO protection schemes — the 63A rating allows upgrade of smaller RCBOs when loads increase, consolidating protection in a single device.
        • Electrical rooms and enclosed plant areas — IP20 sealed design protects against dust and accidental contact within a secure installation location.

        (ALM463T)

        Hager ALM 3 Pole RCBOs are used to provide combined overcurrent and residual current protection for three-phase electrical circuits in residential, commercial, and light industrial installations.

        The range has a 6kA short-circuit breaking capacity, suitable for many commercial and industrial distribution boards.

        A 3 pole RCBO protects three active phases and the neutral, disconnecting all conductors together in the event of a fault.

        The range is available in 10A through to 63A, covering a wide variety of three-phase circuit requirements.

        The range includes C curve options, suitable for general three-phase loads with moderate inrush current.

        Yes. Sparky Direct stocks the Hager ALM 3 Pole RCBO range, with fast dispatch and fast Australia-wide delivery.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Hager Electrical
        SKU ALM463T
        Model # ALM463T
        Package Weight 0.432kg
        TYPE VALUE
        Type Circuit Protection
        Brand Hager Electrical
        Rated Current (A) 63
        Height (mm) 84
        Width (mm) 54
        Depth (mm) 70
        Mounting DIN Rail
        Voltage (V) 400-415
        Wattage (W) 31
        Number of Poles 3P+N
        IP Rating IP20
        Earth Leakage Sensitivity 30mA
        Earth Leakage Protection Class Type A
        Curve C
        Residual Current Type Type A

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products