Skip to main content
Get FREE SHIPPING, BUGLE SCREW BOX and $35 PREZZEE when you shop Clipsal this September! Learn More

Search Results:

    There doesn't appear to be any pages that match your search. Try more general keywords, or just ask us!

    Search Results:

    Product Category Suggestions
      Pages

        NLS | 3P+N RCBO 10A 6kA C Curve | 30mA Type A with Neutral Lead

        The NLS 30933 is a three-module RCBO rated 10A, combining overload, short circuit, and 30mA earth leakage protection in one 3P+N device. The 30933 switches three active poles and carries a solid neutral fed by a 900mm lead. It has a 6kA breaking capacity, a C curve tripping characteristic, and Type A residual current sensing rated 400/415VAC.

        Switchboard upgrades often stall on module count. Adding earth leakage protection to a three-phase circuit usually costs width, and a board already running at capacity has none to give. The 30933 measures 54mm across three standard modules, so it drops into the space a 3 pole MCB already occupies. The existing width stays as it is, and the ways freed elsewhere on the rail stay free.

        Contractors quoting board upgrades price the ways as much as the devices. A three-module RCBO on each three-phase circuit keeps the ways count down, which keeps the enclosure the same size and the quote competitive. The 30933 lands on standard 35mm DIN rail and takes line conductors up to 35mm², so heavy submains terminate straight into the device. The 900mm neutral lead reaches the neutral bar from anywhere on the rail, with a spare crimp ferrule supplied.

        Features

        • 3P+N in three modules — the 30933 switches three active poles and carries a solid neutral, inside the 54mm width of a standard 3 pole MCB.
        • Solid neutral on a 900mm lead — the neutral is not switched; it lands at the bar through a 900mm flying lead, with a spare crimp ferrule supplied.
        • Type A earth leakage sensing — detects sinusoidal AC and pulsating DC residual current, rated at 30mA.
        • 6kA breaking capacity — interrupts prospective fault currents up to 6000A, suited to residential and light commercial board fault levels.
        • C curve tripping — magnetic trip at 5 to 10 times rated current, which allows normal inrush on motor and mixed load circuits.
        • 10A rated current — sized for three-phase final subcircuits drawing up to 10A per phase.
        • 400/415VAC rated — operates at 50/60Hz on standard Australian three-phase supply.
        • Line terminals to 35mm² — the 30933 accepts line conductors up to 35mm² and load conductors up to 25mm², torqued to 2.5Nm.
        • 35mm DIN rail mounting — clips to standard rail without adaptors or backing plates.
        • Tested endurance — rated beyond 6000 electrical operations and 10,000 mechanical operations.
        • IP20 rated — the 30933 is finger-safe at the terminals only, which suits mounting inside a switchboard rather than exposed or damp locations.
        • Not rated for SWER supply — the device is not suitable for 480V single phase SWER installations.

        Where to use

        • Switchboard upgrades — the 30933 replaces an existing 3 pole MCB in the same 54mm width, adding earth leakage protection without widening the board.
        • Three-phase-three-wire circuits — the manufacturer lists motor circuits running without a neutral among the intended applications for this device.
        • Dual-phase appliances — listed by the manufacturer as an intended application, covering appliances that draw across two phases.
        • Three-phase final subcircuits at 10A — sized for small three-phase loads where 10A per phase covers the demand.
        • Boards at module capacity — the three-module footprint fits boards where a wider device would not.
        • Mixed load and motor circuits — the C curve accepts inrush at 5 to 10 times rated current without tripping on start.
        • Retrofit to Type A — the 30933 suits upgrades where an older AC-type device is being replaced with Type A residual current sensing.

        The 30933 is not suitable for 480V single phase SWER supply. It is rated IP20, which suits mounting inside a switchboard enclosure rather than exposed or damp locations. On circuits carrying EMC filtering, such as inverter drives, the filtering can cause unwanted tripping, so confirm the recommended residual current device type with the equipment manufacturer.

        (30933)

        A 3P+N device switches the three active poles and leaves the neutral solid, connected to the neutral bar through a lead. A 4 pole device switches the neutral as well. The NLS 3P+N range fits three standard modules at 54mm, the same width as a 3 pole MCB.

        The range covers 10A, 16A, 20A, 25A, 32A, and 40A. Every rating shares the same 54mm three-module body, 6kA breaking capacity, and C curve tripping. Rating selection must match cable size, load demand, and circuit design under the wiring rules.

        Switchboard work must be carried out by a licensed electrician. The devices clip to standard 35mm DIN rail and occupy 54mm across three modules. Line conductors up to 35mm² and load conductors up to 25mm² terminate at 2.5Nm.

        The neutral lead runs from the device to the switchboard neutral bar. It is 900mm long, and a spare crimp ferrule is supplied with each unit. The neutral pole is solid rather than switched, so only the three active poles open on a trip.

        RCBOs over 110mm in length are exempt from ESV compliance listing, and the DR8L-63 datasheet records the range as exempt on that basis. Confirm current requirements with Energy Safe Victoria before specifying, since exemption scope can change.

        A C curve, with magnetic tripping between 5 and 10 times rated current, which allows normal inrush on motor circuits and mixed loads. Rated residual current options across the range are 10mA, 30mA, and 100mA. Check the individual product listing for the sensitivity of a given model.

        The datasheet records electrical endurance beyond 6000 operations and mechanical endurance beyond 10,000 operations. Operating temperature runs from -5 to +55 degrees C, with storage from -25 to +70 degrees C and tropicalisation tested to 95% relative humidity.

        These devices are not rated for 480V single phase SWER supply. On circuits carrying EMC filtering, such as inverter drives, the filtering can cause unwanted tripping. The manufacturer advises confirming the recommended residual current device type with the equipment manufacturer before specifying.

        The NLS 3P+N RCBO range is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 3 Year
        Commercial Use: 3 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand NATIONAL LIGHT SOURCES
        SKU 30933
        Model # 30933NLS
        Barcode # 9336700018139
        Package Weight 0.424kg
        TYPE VALUE
        Type Circuit Protection
        Brand National Light Sources
        Rated Current (A) 10
        Protection C Curve
        Voltage (V) 400/415
        Number of Poles 3P+N
        IP Rating IP20
        Earth Leakage Sensitivity 30mA
        Earth Leakage Protection Class Type A

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products