        Learn more by watching our HAGER ADM432T | 32 Amp 4 Pole 6kA | 30mA RCD/MCB Combo video.

        Hager | 4 Pole RCBO 32A 6kA 30mA | Type A

        The Hager ADM432T is a 4-pole RCBO (residual current circuit breaker with overload protection) rated 32 amps at 240/415V, combining RCD and MCB protection in a single DIN rail module. The ADM432T carries a 6kA short circuit breaking capacity and 30mA earth leakage sensitivity (Type A residual current), designed for three-phase circuits protecting motors, appliances, and control equipment in residential and commercial installations.

        Licensed electricians specify the ADM432T on three-phase circuits where both overcurrent and earth leakage protection are required at a single point. The 4-pole design suits three-phase plus neutral configurations, simplifying switchboard layouts and reducing the need for multiple separate protection devices. Its C-curve characteristic tolerates the inrush current typical of motor circuits without nuisance tripping.

        The ADM432T combines the operational convenience of a single switching mechanism with the safety redundancy of dual protection. When configured on a three-phase distribution board, it eliminates the labour of separate MCB and RCD installation while delivering the same compliance as a discrete two-device stack. The 30mA sensitivity meets AS/NZS 3000 earth leakage requirements for general-purpose circuits, and Type A residual current provides protection against both AC and pulsating DC fault conditions.

        Features

        • 4-pole configuration — suited to three-phase circuits with neutral, protecting all three phases and the neutral from overcurrent and earth leakage simultaneously.
        • 32-amp rating — handles three-phase loads up to roughly 22 kW at 415V, typical for commercial HVAC, motor-driven equipment, and industrial control circuits.
        • 6kA breaking capacity — rated to safely interrupt fault currents up to 6 kA (6,000 amps) under 240V and 415V supply.
        • 30mA earth leakage sensitivity — detects earth faults as low as 30 mA and trips within 40 milliseconds, protecting personnel and equipment.
        • Type A residual current — responds to AC and pulsating DC fault currents, providing broader protection than Type AC alone in circuits with power electronics.
        • C-curve characteristic — magnetic trip set at 5–10 times the rated current, tolerating the inrush current of motors and compressors without false tripping on start-up.
        • Test button integrated — allows periodic verification of the RCD mechanism without requiring external test equipment; tripping confirms the device is functional.
        • DIN rail mount only — installs on standard DIN rail with top and bottom cage clamp connectors; accepts cable cross-sections from 1 to 25 mm² depending on conductor type.
        • Right neutral position — neutral terminal located on the right side of the module, standard for most switchboard layouts.
        • Manual reset after fault — after earth leakage or overload is cleared, the operating handle must be manually reset; no automatic restrike.
        • Complies with AS/NZS 61009-1 — certified to Australian and New Zealand standards for combined RCD/MCB devices.
        • IP20 protection (IP40 when enclosed) — contact protection rated IP20 on the DIN rail; reaches IP40 when installed in a standard switchboard enclosure.

        Where to use

        • Three-phase motor circuits — the ADM432T protects variable-frequency drives, pump motors, air-conditioning compressors, and other rotating equipment where inrush current is high and both earth leakage and overload protection are required.
        • Three-phase commercial HVAC systems — ideal on the main distribution board for split-system air conditioning units, ducted heating, and ventilation fans where the load can reach or exceed the 32A rating.
        • Industrial control equipment — used on control circuits in workshops, factories, and plant rooms where machinery is supervised and fault tolerance is critical.
        • Three-phase workshop power — secures three-phase power to metal-working machines, automated equipment, and welding apparatus in industrial workshops.
        • Data centre and server room distribution — protects three-phase power distribution boards feeding rack power distribution units and uninterruptible power supplies.
        • Commercial kitchen and laundry — main protection for large cooking equipment, commercial tumble dryers, and other three-phase appliances rated 32A or less.

        The Hager ADM432T is not suitable for single-phase circuits or for three-phase circuits below 32A where a lower-rated device is more appropriate. Do not use the ADM432T on circuits where earth leakage sensitivity greater than 30mA is required (e.g., outdoor or wet locations requiring 10mA protection), nor on installations requiring Type AC only (pulsating DC protection is not needed).

        Verified Sparky Direct customer reviews: Hager ADM432T | 4 Pole 32A 6kA 30mA RCD/MCB Combo (ADM432T)

        "Good quality stuff and good old fashioned customer service." — Fio

        "Works well, a fair price." — Adrian

        "Works perfectly as described, good quality." — James

        (ADM432T)

        An MCB (miniature circuit breaker) trips on overcurrent (short circuits and overloads) and protects wiring and equipment. An RCD (residual current device) trips on earth leakage and protects people from electrocution. The ADM432T combines both in one module, so one DIN rail slot provides dual protection on three-phase circuits.

        The ADM432T mounts directly on a standard DIN rail inside a switchboard. It requires DIN rail space for one four-pole module (approximately 71mm wide) and fits into any switchboard built to AS/NZS 3000 standards with 500V insulation and 2kA dielectric strength.

        No. The ADM432T is rated IP20 (unenclosed) and IP40 (when inside a switchboard enclosure). It is not weatherproof and must not be exposed to rain, condensation, or damp conditions. It is for indoor switchboard use only.

        The 30mA threshold is the earth leakage current at which the RCD will trip. If a person contacts a live conductor, their body provides a path to earth, and if the leakage current exceeds 30mA, the RCD trips within 40 milliseconds (0.04 seconds), typically before serious injury occurs. This meets the safety requirements of AS/NZS 3000 for general-purpose circuits.

        The 32A rating applies to each phase when the ADM432T is installed on a three-phase supply. C-curve tolerance to inrush current applies across all four poles simultaneously. At 415V three-phase, 32A per phase provides roughly 22 kW of load capacity (32A × 415V × 1.73 power factor).

        The Hager ADM432T is available online from Sparky Direct, with Australia-wide delivery to any state or territory including regional areas. Sparky Direct is an Australian electrical wholesaler established in 2005, supplying more than 500,000 customers with transparent trade pricing.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 1 Year
        Commercial Use: 1 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand Hager Electrical
        SKU ADM432T
        Model # ADM432T
        Barcode # 3250611032977
        Package Weight 0.460kg
        TYPE VALUE
        Type Circuit Protection
        Brand Hager Electrical
        Range ADM
        Rated Current (A) 32
        Height (mm) 84
        Width (mm) 71
        Depth (mm) 70
        Standards AS/NZ 61009-1
        Mounting DIN Rail
        Voltage (V) 240/415
        Number of Poles 4
        IP Rating IP20 ( IP40 Enclosed )
        Breaking Capacity 6kA
        Neutral Position Right
        Earth Leakage Sensitivity 30mA
        Earth Leakage Protection Class Type A
        Curve C

        Electrical and HVAC products sold by Sparky Direct are intended for installation by licensed and appropriately qualified professionals in accordance with applicable Australian Standards and regulatory requirements. Customers are responsible for ensuring that any product purchased, including any related or associated components, is compatible and suitable for their intended installation and application.

        Sparky Direct does not provide installation advice and does not assess product suitability for individual circumstances unless expressly confirmed in writing. Customers must confirm correct product selection, compatibility, compliance, and suitability with a licensed or appropriately qualified professional prior to purchase.

        Tools sold by Sparky Direct must be used safely and in accordance with the manufacturer’s instructions. Customers are responsible for ensuring they have the necessary knowledge and competence to operate any tool purchased. If you are unsure how to safely or correctly use a tool, do not use it and seek guidance from the manufacturer or a suitably qualified professional.

        Nothing in this clause limits or excludes any rights or guarantees available under the Australian Consumer Law.

        For website terms and conditions https://www.sparkydirect.com.au/terms-of-use

        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR
        0
        Be The First To Review This Product!

        Help other Sparky Direct users shop smarter by writing reviews for products you have purchased.

        Write a review

        Related Category Products