        NLS 30841 | Single Pole RCBO 6kA | 32Amp A-Type

        The NLS 30841 32A Single Pole RCBO 6kA A Type combines overload, short-circuit and residual current protection in a single compact unit. With Type A functionality, it can detect both AC and pulsating DC leakage, making it compliant with modern wiring rules and ideal for circuits that power electronic appliances.

        This RCBO features pre-attached tails for easy installation and a slim body suited to switchboards with limited space. Fully certified to AS/NZS 61009.1, it offers a dependable solution for new electrical installations or compliance-driven upgrades.

        NLS 30841 Features

        • 32A Current Rating supports higher-load circuits and appliances.
        • Single Pole (1P) RCBO integrates circuit breaker and RCD in one device.
        • 6kA Interrupt Capacity suitable for residential and light commercial applications.
        • Type A Detection responds to both AC and pulsating DC earth leakage faults.
        • DC Tolerant compatible with modern devices that produce DC leakage.
        • Pre-Wired Tails allow quick, tidy installation in tight spaces.
        • Compact Design fits easily into contemporary switchboard layouts.

        Where to use this NLS 30841

        • High-load subcircuits requiring 32A protection and RCD functionality.
        • Switchboard retrofits replacing outdated or non-compliant devices.
        • New installations where Type A compliance is essential.
        • Circuits with electronic loads where DC leakage detection is required.

        (30841)

        It provides overload, short-circuit and earth-leakage protection in one compact module.

        It’s rated 32A, making it suitable for higher-load domestic and light-commercial circuits.

        It offers a 6kA interrupt rating, suitable for typical Australian residential and small commercial fault levels.

        It detects both AC and pulsating DC leakage, aligning with modern appliances and control gear that may introduce DC components.

        Yes, they save time and make neat routing easier in tight boards.

        Yes, Sparky Direct stocks NLS 30841 with quick delivery options depending on location and warehouse availability.

        100-Day Fuss-Free Returns
        We want you to love what you buy—but if you change your mind, that’s okay too. That’s why Sparky Direct offers a 100-day money-back guarantee.

        • Items must be unused, with all parts, accessories, and original packaging.
        • We can’t accept returns if the product is damaged, incomplete, or not in resalable condition.
        • Proof of purchase is required.
        • Return shipping is the responsibility of the customer. 

        If your item isn’t in its original condition, please contact us before returning it—we might save you time and money.


        All products come with a manufacturer’s or supplier’s warranty

        • Warranty starts from the Invoice Date
        • Some suppliers offer in-home warranties and handle claims directly, so you won’t need to uninstall or return the product. Chat with us to check if your product qualifies.
        • Sparky Direct isn’t responsible for losses caused by product failure.
        • Warranties are void if products aren’t installed by a licensed electrician.

        Damaged or Faulty Goods
        If your order arrives damaged or is faulty, let us know within 24 hours.

        • Sparky Direct will pay for return shipping via an emailed return label.
        • If the fault is confirmed, we will send you a replacement item or provide a refund.

        Contact us via our chat to arrange the return.


        Exclusions
        We can’t accept returns for:

        • Items that have been installed, modified, or used
        • Clearance, End of life, Discontinued, or special order items (unless faulty)
        • All PPE Items
        • Goods returned without original packaging or proof of purchase

        How to Request a Return

        1. Contact our customer service team with your order number.
        2. Confirm it’s eligible under our return or warranty policy.
        3. Pack the item securely and return it using a trackable service.
        4. Once we receive and inspect it, we’ll process your refund or replacement.

        Warranty starts from Invoice Date

        Domestic Use: 2 Year
        Commercial Use: 2 Year
        Warranty Method: Return to Sparky Direct

        These specifications and characteristics outline physical, mechanical, electrical details.

        Brand NATIONAL LIGHT SOURCES
        SKU 30841
        Model # 30841NLS
        Barcode # 9336700016708
        Package Weight 0.153kg
        Package Width 0.110m
        Package Height 0.025m
        Package Length 0.090m
        TYPE VALUE
        Type Circuit Protection
        Brand National Light Sources
        Rated Current (A) 32
        Height (mm) 92
        Width (mm) 18
        Depth (mm) 77
        Standards AS/NZ 61009-1
        Mounting Din Rail
        Curve C
        Voltage (V) 240V
        Earth Leakage Protection Class Type A
        Earth Leakage Sensitivity 30mA
        Residual Current 30mA
        Breaking Capacity 6kA
        Overcurrent trip characteristic C Curve
        Earth Fault Wave Form Type A
        IP Rating IP20 ( IP40 Enclosed )
        Number of Poles 1P+N
        0.0

        0 Reviews
        5 STARS
        0
        4 STARS
        0
        3 STARS
        0
        2 STARS
        0
        1 STAR